Audiometru diagnostic MA 52 Test de SISI, DLI, ABLB și Decay
Acest anunț nu mai este activ (data de expirare a fost depașită).
negociabil
Anunț publicat de: Alexe ionLocație: Constanta (Constanta)
Telefon: 0744824905
Data: 23-11-2016
MA 52
PURE-TONE AUDIOMETRY
Air conduction (PURE-TONE AUDIOMETRY) 125-8,000 (octave bands)
Bone conduction (PURE-TONE AUDIOMETRY) 250-6,000octave bands
Continuous or step (PURE-TONE AUDIOMETRY) Step
Intensity, db hl
Air conduction (PURE-TONE AUDIOMETRY)
@ 250 hz (Air conduction) 10 to +100
@ 1,000 hz (Air conduction) 10 to +120
@ 8,000 hz (Air conduction) 10 to +100
Graduations (VACUUM) 1, 2, or 5
Bone conduction (PURE-TONE AUDIOMETRY)
@ 250 hz (Air conduction) 10 to +40
@ 1,000 hz (Air conduction) 10 to +70
@ 4,000 hz (Bone conduction) 10 to +60
Graduations (VACUUM) 5, 2, or 1
Masking, noise type (Bone conduction) Narrow band, speech
Intensity, db spl (Bone conduction) 10 to +100
DIMENSIONS WXDXH,CM (IN) (Bone conduction) 36 x 46 x 15 (13.5 x 17.5 x 6)
WEIGHT, kg (lb) (DISPLAY) 5.8 (12.8)
Type (CONFIGURATION) Wide range
Speech (Bone conduction) Yes
POWER NEEDED
Line, vac (POWER NEEDED) 96/240
BONE VIBRATOR
Type (CONFIGURATION) B-71
SPEECH AUDIOMETRY
Inputs (CHANNELS/INPUT) Multiple options - see commentsMicrophone, tape, CD
Intensity, db hl 10 to +90
Masking, noise type (Bone conduction) Narrow band, speech
Intensity, db spl (Bone conduction) 10 to +100
Headset (OUTPUTS) TDH-39
Cushion (BONE VIBRATOR) Supra-aural
TESTS AVAILABLE ABLB (Fowler), DLI (Luscher), SISI, Stenger, Carhart decay
CONSTELLATION (POWER NEEDED) Tabletop, portable
OTHER ATTRIBUTES (Interference compensation) 2 channels; NOAH compatible; RS232 port; built-in diagnostic tests; built-in amp.
FDA CLEARANCE (Interference compensation) Yes
CE MARK (MDD) (Interference compensation) Yes
MARKETING REGION (Interference compensation) Worldwide
MODEL
MAICO MA 52
PURE-TONE AUDIOMETRY
Frequency, hz (REVOLUTIONS)
Air conduction (PURE-TONE AUDIOMETRY) 125-8,000 (octave bands)
Bone conduction (PURE-TONE AUDIOMETRY) 250-6,000octave bands
Continuous or step (PURE-TONE AUDIOMETRY) Step
Intensity, db hl
Air conduction (PURE-TONE AUDIOMETRY)
@ 250 hz (Air conduction) 10 to +100
@ 1,000 hz (Air conduction) 10 to +120
@ 8,000 hz (Air conduction) 10 to +100
Graduations (VACUUM) 1,2,or 5
Bone conduction (PURE-TONE AUDIOMETRY)
@ 250 hz (Air conduction) 10 to +40
@ 1,000 hz (Air conduction) 10 to +70
@ 4,000 hz (Bone conduction) 10 to +60
Graduations (VACUUM) 5,2,or 1
Masking, noise type (Bone conduction) Narrow band, speech
Intensity, db spl (Bone conduction) 10 to +100
BONE VIBRATOR
Type (CONFIGURATION) B-71
DIMENSIONS WXDXH,CM (IN) (Bone conduction) 36x 46 x 15 (13.5x 17.5 x 6)
WEIGHT, kg (lb) (DISPLAY) 5.8(12.8)
Type (CONFIGURATION) Wide range
Speech (Bone conduction) Yes
SPEECH AUDIOMETRY
Inputs (CHANNELS/INPUT) Multiple options - see commentsMicrophone, tape, CD
Intensity, db hl 10 to +90
Masking, noise type (Bone conduction) Narrow band, speech
Intensity, db spl (Bone conduction) 10 to +100
Headset (OUTPUTS) TDH-39
Cushion (BONE VIBRATOR) Supra-aural
TESTS AVAILABLE ABLB (Fowler), DLI (Luscher), SISI, Stenger, Carhart decay
POWER NEEDED
Line, vac (POWER NEEDED) 96/240
CONSTELLATION (POWER NEEDED) Tabletop, portable
OTHER ATTRIBUTES (Interference compensation) 2channels; NOAH compatible; RS232 port; built-in diagnostic tests; built-in amp.
FDA CLEARANCE (Interference compensation) Yes
CE MARK (MDD) (Interference compensation) Yes
MARKETING REGION (Interference compensation) Worldwide
Trimite un mesaj către Alexe ion: